A technical reference for decoding Samsung EHS heat pump telemetry from the SmartThings ehsCycleData capability.
Samsung EHS heat pumps expose operational telemetry through the samsungce.ehsCycleData SmartThings capability. This contains hex-encoded binary data for both outdoor and indoor units, encoding temperatures, flow rates, compressor frequency, and pump speeds.
The byte positions map to Samsung NASA (Network Air-conditioning Smart Application) protocol registers — the same registers accessible via MIM-B19N Modbus modules or ESPHome HVAC bus integrations, but encoded into hex blobs by the SmartThings cloud.
Samsung EHS heat pumps report telemetry through two SmartThings components: an outdoor unit (compressor, ambient conditions) and an indoor unit (water circuit, pump, flow). Each component's cycle data is a hex-encoded binary blob that varies in length depending on the device model.
Different device models produce different data lengths with subtly different byte layouts. Dwellsee uses a binaryId-keyed architecture to select the correct byte layout for each device:
binaryId (firmware identifier) is recognised, use its registered byte layoutEach Samsung EHS heat pump reports a binaryId that identifies its firmware and platform. This determines the indoor data length and byte layout.
| binaryId | Indoor | Outdoor | Component | Flow Rate |
|---|---|---|---|---|
| SAC_EHS_MONO | 31B | 28B | INDOOR | bytes[6–7] uint16 BE / 10 (LPM) |
| SAC_EHS_SPLIT | 31B | 28B | INDOOR | bytes[6–7] uint16 BE / 10 (LPM) |
| SAC_DVM_HE | 24B | 18B | INDOOR | byte[7] direct (integer LPM) |
| TP1X_DA_AC_EHS_01001_0000 | 31B | 28B | INDOOR1 | bytes[6–7] uint16 BE / 10 (LPM) |
| S905D3_SAC_EHS_24 | 36B | 28B | INDOOR1 | bytes[6–7] uint16 BE / 10 (LPM) |
Samsung EHS heat pumps have a temperatureReference setting that controls what the indoor temperature sensor measures:
Water reference (default)
The SmartThings temperatureMeasurement.temperature value on the INDOOR component reports the water flow temperature. Indoor cycle data byte[4] is 0x05 (a null sentinel).
Air reference
The INDOOR temperatureMeasurement.temperature reports the room air temperature instead. The water flow temperature is available at indoor cycle data byte[4] − 55 (°C).
The temperatureReference setting is reported by the samsungce.ehsTemperatureReference capability. To correctly decode flow temperature for all devices, check this value and use byte[4] only when the reference is “air” and byte[4] is not 0x05.
Outdoor data length varies by device (18 or 28 bytes). Both formats share the same byte positions for the first 18 bytes.
Position: 0 1 2 3 4 5 6 7 8
^^^^^ ^^^^^ ^^ ^^ ^^ ^^
| | | | | |
| | | | | outdoor temp (byte − 55)
| | | | suction temp* (byte − 55)
| | | outdoor coil temp* (byte − 55)
| | discharge temp (byte − 55)
| target compressor freq (int16 BE, Hz)
current compressor freq (int16 BE, Hz)
* fleet-checked, not compared with a physical sensor| Position | Field | Formula | Status |
|---|---|---|---|
| Bytes 0–1 | Compressor frequency | int16 BE (Hz) | Cross-referenced |
| Bytes 2–3 | Target compressor frequency | int16 BE (Hz) | Cross-referenced |
| Byte 5 | Discharge gas temperature | byte − 55 (°C) | Cross-referenced |
| Byte 6 | Outdoor coil (evaporating) temperature | byte − 55 (°C) | Fleet-checked |
| Byte 7 | Suction line temperature | byte − 55 (°C) | Fleet-checked |
| Byte 8 | Outdoor temperature | byte − 55 (°C) | Validated |
18-byte example
00 1E 00 1E 5E 75 3B FF 3E 02 00 F1 01 C2 00 01 00 0028-byte example
00 32 00 32 5E 59 3A 3A 3C 02 02 65 01 F4 00 02 00 00 00 27 00 58 32 5F 00 00 00 000xFF and 0x00 mean no reading. Byte 5 (discharge temperature) has no reading on about 1 in 5 SAC_EHS_MONO units (0xFF) and S905D3 units (0x00). Byte 4 is not a substitute: it is a different reading that runs about 15°C cooler (likely condensing temperature).Used by INDOOR components on SAC_DVM_HE, and by SAC_EHS_MONO / SAC_EHS_SPLIT units before the firmware update rolled out from 2026-03-31 (they now send the 31-byte format). Flow rate is encoded as an integer.
Position: 0 1 2 3 4 5 6 7 8 9
^^ ^^ ^^ ^^ ^^ ^^
| | | | | |
| | | | | pump speed (byte = %)
| | | | flow rate (LPM, integer)
| | | flow temp (byte − 55, air-ref only)
| | return water temp (byte − 55)
| evaporator OUT temp (byte − 55)
evaporator IN temp (byte − 55)| Position | Field | Formula | Status |
|---|---|---|---|
| Byte 0 | Evaporator inlet temperature | byte − 55 (°C) | Cross-referenced |
| Byte 1 | Evaporator outlet temperature | byte − 55 (°C) | Cross-referenced |
| Byte 2 | Return water temperature | byte − 55 (°C) | Cross-referenced |
| Byte 4 | Flow temperature (air-reference only) | byte − 55 (°C) | Validated |
| Byte 7 | Flow rate | byte directly (LPM) | Validated |
| Byte 8 | Inverter pump speed | byte directly (%) | Validated |
24-byte example (water-reference device)
56 58 54 05 56 05 00 22 42 00 00 00 00 00 00 00 00 01 00 00 00 0B 14 21Used by INDOOR1 components on the TP1X platform (TP1X_DA_AC_EHS_01001_0000), and by SAC_EHS_MONO / SAC_EHS_SPLIT units since the 2026-03-31 firmware update. Flow rate has decimal precision (SAC_EHS units report whole litres, e.g. 0x00F0 = 24.0).
Position: 0 1 2 3 4 5 6 7 8 9
^^ ^^ ^^^^^ ^^
| | | |
| | | pump speed (byte = %)
| | flow rate (uint16 BE / 10 = LPM)
| flow temp (byte − 55)
return water temp (byte − 55)| Position | Field | Formula | Status |
|---|---|---|---|
| Byte 2 | Return water temperature | byte − 55 (°C) | Cross-referenced |
| Byte 3 | Flow temperature | byte − 55 (°C) | Validated |
| Bytes 6–7 | Flow rate | uint16 BE / 10 (LPM) | Validated |
| Byte 8 | Inverter pump speed | byte directly (%) | Validated |
31-byte example
4E 05 4E 50 05 05 00 D2 64 00 00 00 00 00 00 00 00 01 00 00 00 01 B3 B3 00 00 00 6F 05 05 4B01 36 is 31.0 LPM, not 5.4.006E, then 2AF8 (11000), then ADB0 (110000 truncated). 8000 also appears. Seen both via the SmartThings cloud and in local device reads, so it originates on the device side. Discard any value above 60 LPM (no genuine fleet reading exceeds ~50 LPM).dhwTemp value.Used by INDOOR1 components on the S905D3 platform (S905D3_SAC_EHS_24, e.g. Samsung E50AJTAE1). Shares the same prefix layout as the 31-byte format with 5 additional trailing bytes.
| Position | Field | Formula | Status |
|---|---|---|---|
| Byte 2 | Return water temperature | byte − 55 (°C) | Cross-referenced |
| Byte 3 | Flow temperature | byte − 55 (°C) | Cross-referenced |
| Bytes 6–7 | Flow rate | uint16 BE / 10 (LPM) | Validated |
| Byte 8 | Inverter pump speed | byte directly (%) | Cross-referenced |
0x009F = 15.9 LPM matched the controller's 16 LPM display.Summary of all formulas used to convert raw bytes into meaningful values.
| Formula | Result | Used for |
|---|---|---|
| byte − 55 | Temperature (°C) | Outdoor temp, discharge temp, return water temp, flow temp, evaporator temps |
| uint16 BE / 10 | Flow rate (LPM) | 31-byte and 36-byte indoor formats, bytes 6–7 (discard values above 60 LPM) |
| byte directly | Flow rate (LPM) | 24-byte indoor format (integer precision) |
| byte directly | Pump speed (%) | Inverter pump speed, all indoor formats (byte 8) |
| int16 BE | Frequency (Hz) | Compressor frequency (outdoor bytes 0–1) |
| int16 BE / 10 | Flow rate (LPM) | Outdoor bytes 20–21 — NOT a flow measurement; meaning unknown |
The cycle data bytes correspond to Samsung NASA protocol registers. This mapping helps cross-reference hex decoding against the well-documented Modbus register tables used by MIM-B19N modules and ESPHome integrations.
| Cycle Data | Register | Name | Decoding |
|---|---|---|---|
| Outdoor bytes 0–1 | 0x8238 | Compressor 1 Current Freq | int16 BE (Hz) |
| Outdoor bytes 2–3 | 0x8236/0x8237 | Compressor Target Freq | int16 BE (Hz) |
| Outdoor byte 5 | 0x820A | Discharge 1 Temperature | byte − 55 (°C) |
| Outdoor byte 6 | ~0x8205 | Evap Saturation Temp | byte − 55 (°C) |
| Outdoor byte 7 (28-byte) | ~0x8206 | Suction Temperature | byte − 55 (°C) |
| Outdoor byte 8 | 0x8204 | Outdoor Temperature | byte − 55 (°C) |
| Indoor byte 0 (24-byte) | ~0x82DE | EVA In Temperature | byte − 55 (°C) |
| Indoor byte 1 (24-byte) | ~0x8218 | Heat Exchanger Outlet | byte − 55 (°C) |
| Indoor byte 2 | ~0x42D9 | Water Inlet (Return) | byte − 55 (°C) |
| Indoor bytes 6–7 | 0x42E9 | Water Flow | LPM (see format) |
| Indoor byte 8 | 0x40C4 | PWM Water Pump | byte directly (%) |
Registers prefixed with ~ are approximate mappings based on value correlation, not confirmed by Samsung documentation.
Cycle data does not update when the system is off. When both the main system switch and heating circuit are off, the hex data is stale and reflects the last active reading.
This has important implications for consumers of decoded data:
Each decoded field has been validated or cross-referenced using one or more of the following methods:
24 hours of telemetry data compared against weather station readings. Formula byte[8] − 55 achieved r = 0.865 correlation, with 75% of hourly readings within ±1°C.
Compared against physical flow meter readings during system startup. Indoor bytes[6–7] / 10 matched actual readings exactly (e.g. 21.0 LPM vs 21 LPM actual), while the outdoor-derived value was consistently wrong (4.4–9.4 LPM for the same period).
Analysis of ~380,000 samples from 92 SAC_EHS_MONO units plus TP1X, S905D3 and SAC_EHS_SPLIT units. Where byte 6 flips between 0 and 1, the median step between consecutive readings is 4.0 LPM when bytes 6–7 are read as one uint16, versus 21.6 LPM when byte 7 is read alone. The uint16 reading also raises the correlation between thermal output and compressor frequency (S905D3 0.43 → 0.61, TP1X 0.39 → 0.59). Prompted by a user report of an implausible, constant flow reading.
Validated across multiple readings showing plausible correlation between flow rate, compressor frequency, and flow temperature. Formula is byte[7] directly (integer LPM). Range observed: 13–39 LPM during active heating.
Confirmed by comparing stored telemetry against device display photos taken at known times. The byte value is used directly as the pump speed percentage (e.g. byte value 71 = 71%).
Decoded values were compared against a Home Assistant dashboard powered by a hardware NASA bus integration. This confirmed compressor frequency, discharge temperature, evaporator temps, and return water temperature fields. Values taken at different timestamps showed plausible variation.
Pearson correlation analysis of 1,313 data points from a TP1X_DA_AC_EHS_01001_0000 device across 10 days of 5-minute samples. Outdoor byte[6] and byte[7] both tracked outdoor temperature with byte[6] averaging ~3°C below ambient (consistent with evaporator saturation) and byte[7] 1–2°C above byte[6] (consistent with suction superheat). Both are physically plausible but have not yet been cross-referenced against a hardware NASA bus integration.
Raw cycle data from 144 devices across every binaryId and format (22,500 distinct samples from a February and a November day). On every model, byte[6] equals outdoor temperature when idle and sits 2–4°C below it while heating, so it is the outdoor coil (evaporating) temperature. Byte[5] tracks compressor frequency within each unit (median r ≈ 0.7) and climbs after start-up, as discharge temperature should. Byte[7] sits 0–1°C above byte[6] while heating (suction) and also exists in the 18-byte format. Discharge runs about 12°C above flow temperature on TP1X and S905D3 units and about 30–40°C above it on MONO and SPLIT units.
Important notes